Lined Piping Systems

Lined Piping Systems

  • Infinity Lining Pvt.Ltd Supply PTFE / Antistatic PTFE / PVDF / PP / HDPE Lined Pipes. The Maximum Length of the PTFE Lined Pipes can be up to maximum 6000mm which depends on the size of Pipe.
  • PTFE Liners are made from the process of the Paste Extrusion Process and then they are sintered in Ovens. PTFE Lined Pipes are passed through Quality Checks like Visual, Dimensional, Hydro, Electrostatic Test as mentioned in ASTM F 1545. PTFE Liners are tested for their Tensile Strength in Tensile Testing Machine. PTFE Lined Pipes are supplied with One End Loose Flange and One End Fix Flange. For Smaller Lengths we provide PTFE Lined Spacers which are specially used for Length Smaller than 100 mm.

PTFE / Antistatic PTFE Lined Pipes


Lined Pipe Spool


SS Lined Pipe Spool


SS PTFE Lined Pipe Spool

  • Infinity Lining Pvt.Ltd Provides PTFE / Antistatic PTFE Lined Pipes from 25 NB TO 450 NB Size.
  • Infinity Lining Pvt.Ltd has own In-house Fabrication, Extrusion, Lining and Flaring department for manufacturing of PTFE / Antistatic PTFE Lined Pipes.
    The Pipe Material used is 106 Grade B Sch 40 from 25 NB to 150 NB and above Sch 20 Pipes are used. The Flanges normally used are of ASTM A 105/IS 2062.
  • Resin used for Making PTFE Liners is procured from DuPont.
    The pipe spools are lined with an interference fit paste extruded PTFE liner flared at each end to raised face dimensions giving all wetted parts in PTFE. Up to 6″ NB the pipe spools use heavy duty PTFE liner suitable for vacuum performance. Above 6″NB we offer both heavy wall vacuum rated liners and standard wall liners as appropriate for the application.
  • ALL CS/PTFE Lined Pipes are tested as Per ASTM F 1545 Which Includes Visual, Dimensional, Hydro Test at 29.8 Kg/cm2 and Spark Test 15 KVA.
    Material is supplied with Material Test Certificate and Internal Test Reports.

PTFE / Antistatic PTFE Jacketed Pipe


Lined Jacketed Pipe Spool

  • Infinity Lining Pvt.Ltd Provides PTFE / Antistatic PTFE Lined Pipes from 25 NB TO 150 NB Size.
    The Pipe Material used is 106 Grade B Sch 40 from 25 NB to 150 NB.
  • The Flanges normally used are of ASTM A 105/IS 2062.Resin used for Making PTFE Liners is Procured from DuPont.
  • ALL CS/PTFE Jacketed Lined Pipes are tested as Per ASTM F 1545 Which Includes Visual, Dimensional, Hydro Test at 29.8 Kg/cm2 and Spark Test 15 KVA.
  • Material is supplied with Material Test Certificate and Internal Test Reports.

PP / PVDF / HDPE Lined Pipes


PP Lined Pipes

  • Infinity Lining Pvt.Ltd Provides PP / PVDF / HDPE Lined Pipes from 25 NB TO 300 NB Size.
  • The Pipe Material used is 106 Grade B Sch 40 from 25 NB to 150 NB and above Sch 20 Pipes are used / ERW Medium B Class.
  • The Flanges used are of ASTM A 105/IS 2062.
  • Infinity Lining Pvt.Ltd Procures PP / PVDF / HDPE Lining Liners Directly from Manufactures and do Lining in the Pipes.|
  • ALL CS/PP Lined Pipes are tested as Per ASTM F 1545 Which Includes Visual, Dimensional, Hydro Test at 29.8 Kg/cm2 and Spark Test 15 KVA.
  • Material is supplied with Material Test Certificate and Internal Test Reports.

Lined Elbows

PTFE / FEP / PFA / Antistatic PTFE / PP / PVDF / HDPE Lined 45 Degree / 90 Degree Elbows

    • 45 Degree Elbow Size : 25 NB TO 450 NB
    • 90 Degree Elbow Size : 25 NB TO 200 NB
    • Bend Outer Body ASTM A 234 Gr WPB SCH-40/SS 304/SS 316
    • Flange ASTM A 105/IS 2062
    • Lining: PTFE / FEP / PFA / Antistatic PTFE / PP / PVDF / HDPE
    • Resin used for Making PTFE Liners is procured from DuPont
  • ALL MS PTFE Lined Elbows are tested as Per ASTM F 1545 Which Includes Visual, Dimensional, Hydro Test at 29.8 Kg/cm2 and Spark Test 15 KVA.
  • Infinity Lining Pvt.Ltd Procures PP / PVDF / HDPE Lining Liners Directly from Manufactures and do Lining in the Elbows.

45 Degree Elbow


SS 90 & 45 Degree Elbow

Lined Tees

PFA / FEP / Antistatic PFA / PP / PVDF Lined Equal Tee


FEP, PFA, PP Lined Equal Tee

      • Size: 25 NB TO 300 NB
      • Bend Outer Body ASTM A 395 Gr 60-40-18 / Fabricated from 106 Grade B Pipe schedule 40 with IS620 Flanges / A105 Flanges.
      • Flange Connection: ANSI B 16.5
      • Face to Face: ANSI B 16.10
      • Spark Testing at 15 KVA
      • Hydro Test at 29.8 kg/cm2

Material is supplied with Material Test Certificate and Internal Test Reports.

PFA / FEP / Antistatic PFA / PP / PVDF / HDPE Lined Reducing Tee

PP Lined Un Equal Tee

SS Un Equal Tee

SS Un Equal Tee

      • Size: 25 NB TO 300 NB
      • Bend Outer Body ASTM A 395 Gr 60-40-18 / Fabricated from 106 Grade B Pipe schedule 40 with IS620 Flanges / A105 Flanges.
      • Flange Connection: ANSI B 16.5
      • Face to Face: ANSI B 16.10
      • Spark Testing at 15 KVA
      • Hydro Test at 29.8 kg/cm2

Material is supplied with Material Test Certificate and Internal Test Reports.

PFA / FEP / Antistatic PFA / PP / PVDF / HDPE Lined Instrument Tee


PFA Lined Instrument Tee


PP Lined Instrument tee

      • Size: 25 NB TO 300 NB
      • Bend Outer Body ASTM A 395 Gr 60-40-18 / Fabricated from 106 Grade B Pipe schedule 40 with IS620 Flanges / A105 Flanges.
      • Flange Connection: ANSI B 16.5
      • Face to Face: ANSI B 16.10
      • Spark Testing at 15 KVA
      • Hydro Test at 29.8 kg/cm2

Material is supplied with Material Test Certificate and Internal Test Reports.

PFA / FEP / Antistatic PFA / PP / PVDF / HDPE Lined Equal Cross


Equal Cross

      • Size: 25 NB TO 300 NB
      • Bend Outer Body ASTM A 395 Gr 60-40-18 / Fabricated from 106 Grade B Pipe schedule 40 with IS620 Flanges / A105 Flanges.
      • Flange Connection: ANSI B 16.5
      • Face to Face: ANSI B 16.10
      • Spark Testing at 15 KVA
      • Hydro Test at 29.8 kg/cm2

Material is supplied with Material Test Certificate and Internal Test Reports.

Lined Reducers

PFA / FEP / Antistatic PFA / PP / PVDF / HDPE Lined Reducers


Concentric reducer


PFA Lined Concentric Reducer


PP Lined Concentric Reducer

      • Size: 25 NB TO 300 NB
      • Bend Outer Body ASTM A 395 Gr 60-40-18 / Fabricated from 106 Grade B Pipe schedule 40 with IS620 Flanges / A105 Flanges.
      • Flange Connection: ANSI B 16.5
      • Face to Face: ANSI B 16.10
      • Spark Testing at 15 KVA
      • Hydro Test at 29.8 kg/cm2

Material is supplied with Material Test Certificate and Internal Test Reports.

PFA / FEP / Antistatic PFA / PP / PVDF / HDPE Eccentric Reducers


Eccentric Reducer


PP Lined Eccentric Reducer

    • Infinity Lining Pvt.Ltd Provides PTFE / FEP / PFA / Antistatic PTFE / PP / PVDF / HDPE Lined Elbows.
      • Size: 25 NB TO 300 NB
      • Bend Outer Body ASTM A 395 Gr 60-40-18 / Fabricated from 106 Grade B Pipe schedule 40 with IS620 Flanges / A105 Flanges.
      • Flange Connection: ANSI B 16.5
      • Face to Face: ANSI B 16.10
      • Spark Testing at 15 KVA
      • Hydro Test at 29.8 kg/cm2

Material is supplied with Material Test Certificate and Internal Test Reports.

PFA / FEP / Antistatic PFA / PP / PVDF / HDPE Lined Reducing Flanges


FEP & PFA Lined Reducing Flange


PP Reducing Flange

      • Size: 25 NB TO 300 NB
      • Bend Outer Body ASTM A 395 Gr 60-40-18 / Fabricated from 106 Grade B Pipe schedule 40 with IS620 Flanges / A105 Flanges.
      • Flange Connection: ANSI B 16.5
      • Face to Face: ANSI B 16.10
      • Spark Testing at 15 KVA
      • Hydro Test at 29.8 kg/cm2

Material is supplied with Material Test Certificate and Internal Test Reports.

Spacers

PFA / FEP / Antistatic PFA / PP / PVDF / HDPE Lined Spacers


PTFE Lined Spacer

      • Size: 25 NB TO 300 NB
      • Bend Outer Body ASTM A 395 Gr 60-40-18 / Fabricated from 106 Grade B Pipe schedule 40 with IS620 Flanges / A105 Flanges.
      • Flange Connection: ANSI B 16.5
      • Face to Face: ANSI B 16.10
      • Spark Testing at 15 KVA
      • Hydro Test at 29.8 kg/cm2

Material is supplied with Material Test Certificate and Internal Test Reports.

PTFE Spacers


PTFE Spacer


PTFE Spacer

      • Size: 25 NB TO 300 NB
      • Length:3mm to 200mm
      • Temprature: PTFE –Max 200 Degree Celsius

Material is supplied with Material Test Certificate and Internal Test Reports.

Blind Flange

PFA / FEP / PP / PVDF / HDPE Lined Blind Flanges


PTFE Lined Blind Flanges

      • Size: 25 NB TO 300 NB
      • Bend Outer Body ASTM A 395 Gr 60-40-18 / Fabricated from 106 Grade B Pipe schedule 40 with IS620 Flanges / A105 Flanges.
      • Flange Connection: ANSI B 16.5
      • Face to Face: ANSI B 16.10
      • Spark Testing at 15 KVA
      • Hydro Test at 29.8 kg/cm2

Material is supplied with Material Test Certificate and Internal Test Reports.

MATERIAL TEMPERATURE RANGE, ℉ ( ℃ )
Perfluoro (Alkoxyalkane) Copolymer (PFA) -20 to 500 (-29 to 260)
Perfluoro (Ethylene – Propylene)) Copolymer (FEP) -20 to 300 (-29 to 149)
Poly (VinylideneFluride) (PVDF) 0 to 275 (-18 to 135)
Poly (VinylideneFluride) Copolymer (PVDF) -20 to 500 (-29 to 135)
Polytetrafluoroethylene (PTFE) -20 to 500 (-29 to 260)
Propylene and Polypropylene (PP) 0 to 225 (-18 to 107)